GCK Low-voltage Fixed Switchgear

GCK (functionally equivalent to or superior to (3CL) low-voltage withdrawable complete switchgear (hereinafter referred to as "switchgear") is suitable for ratedworking voltage of 380V, AC three-phase network line, three-phase five wire system, as power plants, substations, industrial and mining enterprises, and high-risebuildings in the power system for receiving, feeding, reactive power compensation, energy metering, lighting,and centralized control of motors.

Keywords:

GCK Low-voltage Fixed Switchgear

WhatsApp:

Product Description

  • 产品描述
  • Overview

    ● GCK (functionally equivalent to or superior to (3CL) low-voltage withdrawable complete switchgear (hereinafter referred to as "switchgear") is suitable for ratedworking voltage of 380V, AC three-phase network line, three-phase five wire system, as power plants, substations, industrial and mining enterprises, and high-risebuildings in the power system for receiving, feeding, reactive power compensation, energy metering, lighting,and centralized control of motors.

    ● This product meets the standards of GB7251 "Voltage Complete Switchgear and Control Equipment" JB/T9661 "Voltage Withdrawable Switchgear" and IEC 439"Low Voltage Complete Switchgearand Control Equipment".

    Normal condition

    ● Altitude:2000m and below.

    ● Environmental temperature:-5℃~+40 。C, with a daily average temperature notexceeding+35℃.

    ● Relative humidity: does not exceed 50% at a temperature of+40 ℃, and allows for higherrelative humidity at lower temperatures, which may result in occasional condensation of cattle;For example,at+20C,it is 90%.

    ● Places without fire, explosion hazards, severe pollution, chemical corrosion, and severevibration.

    ● The inclination from the vertical plane shall not exceed 5 °.

    ● Applicable to transportation and storage processes at temperatures ranging from -25℃to+55 °C, and within a short period of time (not exceeding 24L1) not exceeding+70°℃.

    ● lf the above usage conditions cannot be met, the user should propose to our company atthe time of ordering and negotiate for a solution.

    Main technical parameters

    Project Parameter
    Rated insulation voltage 660V、1000V;
    Rated working voltage 380V、660V;
    Rated voltage of auxiliary circuit AC220V、380V、DC110V、220V;
    Rated frequency 50Hz~(60)Hz;
    Rated current Horizontal busbar≤31.5A; 垂Vertical busbar630A、800A,1200A
    Rated short time withstand current 50、80kA/1S, Neutral busbar30kA/1S;
    Rated peak current 105kA/0.1S,50kA/0.1S;
    Functional unit (drawer) breaking capacity 50kA ( Valid value);
    Housing protection level IP30、IP40;
    Bus settings hree phase four wire system and three phase five wire system;
    Operation mode Local, remote, and automatic.

     